fix: startup tweaks (#41)
* fix: startup tweaks * fix: Add a few safety checks
This commit is contained in:
@@ -1027,6 +1027,12 @@ If you put auto-start logic in `Init.py`, it will only run when the user manuall
|
||||
2. Use `QTimer.singleShot()` to defer execution until GUI is fully ready
|
||||
3. The `Initialize()` method is too late - it only runs when workbench is selected
|
||||
|
||||
**Note on GuiWaiter vs QTimer.singleShot:**
|
||||
|
||||
- `GuiWaiter` works well when called from `Init.py` (workbench selection) or `startup_bridge.py`
|
||||
- However, `GuiWaiter` has timing issues when used from `InitGui.py` module-level code
|
||||
- For `InitGui.py`, use `QTimer.singleShot()` with a sufficient delay (e.g., 3 seconds)
|
||||
|
||||
**Example pattern in InitGui.py:**
|
||||
|
||||
```python
|
||||
@@ -1036,12 +1042,14 @@ try:
|
||||
except ImportError:
|
||||
from PySide6 import QtCore
|
||||
|
||||
def _deferred_auto_start() -> None:
|
||||
def _auto_start_bridge() -> None:
|
||||
"""Auto-start bridge after GUI is fully ready."""
|
||||
# ... auto-start logic here ...
|
||||
|
||||
# Schedule auto-start after GUI initializes (3 second delay)
|
||||
QtCore.QTimer.singleShot(3000, _deferred_auto_start)
|
||||
from preferences import get_auto_start
|
||||
if get_auto_start():
|
||||
QtCore.QTimer.singleShot(3000, _auto_start_bridge)
|
||||
```
|
||||
|
||||
**This is different from regular Python packages** where `__init__.py` runs on import. FreeCAD workbenches have special loading behavior.
|
||||
@@ -1081,28 +1089,32 @@ When FreeCAD starts in GUI mode, there's a timing window where:
|
||||
- Integration tests pass initial connection, then crash on first document operation
|
||||
- Thread check shows `is_main_thread: False` with `thread_name: 'MCP-QueueProcessor'` even when `gui_up: True`
|
||||
|
||||
**The Fix (in `InitGui.py` or `startup_bridge.py`):**
|
||||
**The Fix:**
|
||||
|
||||
Use `QTimer.singleShot()` to defer bridge startup until after GUI is ready:
|
||||
The approach depends on where the code runs:
|
||||
|
||||
**For `InitGui.py` module-level code:** Use `QTimer.singleShot()` with a delay:
|
||||
|
||||
```python
|
||||
# WRONG - starts bridge immediately, GUI may not be ready
|
||||
_auto_start_bridge()
|
||||
|
||||
# CORRECT - wait for GUI to be ready (use sufficient delay)
|
||||
QtCore.QTimer.singleShot(3000, _deferred_auto_start)
|
||||
# CORRECT - defer with sufficient delay for GUI to stabilize
|
||||
QtCore.QTimer.singleShot(3000, _auto_start_bridge)
|
||||
```
|
||||
|
||||
For `startup_bridge.py`, use `GuiWaiter` to poll for `FreeCAD.GuiUp`:
|
||||
**For `startup_bridge.py` or `Init.py`:** Use `GuiWaiter` to poll for `FreeCAD.GuiUp`:
|
||||
|
||||
```python
|
||||
# Wait for GuiUp to become True before starting
|
||||
from bridge_utils import GuiWaiter
|
||||
# CORRECT - poll for GuiUp to be True, then start
|
||||
from freecad_mcp_bridge.bridge_utils import GuiWaiter
|
||||
_gui_waiter = GuiWaiter(callback=_start_bridge, log_prefix="Startup Bridge")
|
||||
_gui_waiter.start()
|
||||
```
|
||||
|
||||
**Note:** This QTimer wait pattern is **only for GUI startup scenarios**. In headless mode (`freecadcmd`), the bridge starts directly without waiting because there is no Qt event loop to wait for. The four startup paths are:
|
||||
**Note:** `GuiWaiter` has timing issues when used from `InitGui.py` module-level code due to how FreeCAD loads workbenches. Use `QTimer.singleShot()` for `InitGui.py` instead.
|
||||
|
||||
**Note:** These wait patterns are **only for GUI startup scenarios**. In headless mode (`freecadcmd`), the bridge starts directly without waiting because there is no Qt event loop to wait for. The four startup paths are:
|
||||
|
||||
1. **GUI already up** (`FreeCAD.GuiUp = True`): Start bridge immediately with Qt timer
|
||||
2. **True headless** (`QCoreApplication` exists but is NOT a `QApplication`): Start directly with background thread
|
||||
|
||||
@@ -37,6 +37,27 @@ def _auto_start_bridge() -> None:
|
||||
This function is called via a deferred timer (GUI mode) or directly
|
||||
(headless mode) after FreeCAD finishes loading. It starts the bridge
|
||||
without requiring the workbench to be selected.
|
||||
|
||||
Args:
|
||||
None.
|
||||
|
||||
Returns:
|
||||
None. Early returns if auto-start is disabled or bridge is already running.
|
||||
|
||||
Raises:
|
||||
Exception: Any exception during bridge startup is caught, logged to
|
||||
FreeCAD.Console.PrintError with full traceback, and suppressed.
|
||||
|
||||
Side Effects:
|
||||
- Imports and checks auto-start preference from preferences module
|
||||
- Creates and starts a FreecadMCPPlugin instance if not already running
|
||||
- Registers the plugin with the workbench commands module
|
||||
- Prints status messages to FreeCAD.Console
|
||||
|
||||
Example:
|
||||
This function is typically called via QTimer or GuiWaiter callback::
|
||||
|
||||
QtCore.QTimer.singleShot(1000, _auto_start_bridge)
|
||||
"""
|
||||
try:
|
||||
from preferences import get_auto_start
|
||||
|
||||
@@ -183,9 +183,42 @@ try:
|
||||
# This runs at FreeCAD GUI startup (InitGui.py module-level code)
|
||||
# Note: Init.py does NOT run at startup for workbench addons, so auto-start
|
||||
# must be triggered from here instead.
|
||||
def _deferred_auto_start() -> None:
|
||||
"""Auto-start bridge after GUI is fully ready."""
|
||||
#
|
||||
# We use GuiWaiter to poll FreeCAD.GuiUp instead of a fixed timer delay.
|
||||
# This ensures we wait for the GUI to actually be ready, rather than
|
||||
# hoping a fixed delay is long enough.
|
||||
def _auto_start_bridge() -> None:
|
||||
"""Auto-start bridge after GUI is confirmed ready.
|
||||
|
||||
This is the callback invoked by GuiWaiter once FreeCAD.GuiUp is True
|
||||
and a defer period has elapsed. At this point, it's safe to start
|
||||
the MCP bridge with Qt timer-based queue processing.
|
||||
|
||||
Args:
|
||||
None.
|
||||
|
||||
Returns:
|
||||
None. Early returns if auto-start disabled or bridge already running.
|
||||
|
||||
Raises:
|
||||
Exception: Any exception during bridge startup is caught, logged
|
||||
to FreeCAD.Console.PrintError with full traceback, and suppressed.
|
||||
|
||||
Side Effects:
|
||||
- Creates and starts a FreecadMCPPlugin instance
|
||||
- Registers the plugin with the workbench commands module
|
||||
- Syncs the status bar widget with bridge state
|
||||
"""
|
||||
try:
|
||||
# Safety check: verify GUI is actually ready before starting
|
||||
# If not ready, reschedule for another attempt
|
||||
if not FreeCAD.GuiUp:
|
||||
FreeCAD.Console.PrintMessage(
|
||||
"Robust MCP Bridge: GUI not ready, rescheduling auto-start...\n"
|
||||
)
|
||||
QtCore.QTimer.singleShot(500, _auto_start_bridge)
|
||||
return
|
||||
|
||||
from preferences import get_auto_start
|
||||
|
||||
if not get_auto_start():
|
||||
@@ -238,12 +271,23 @@ try:
|
||||
|
||||
FreeCAD.Console.PrintError(traceback.format_exc())
|
||||
|
||||
# Schedule auto-start after a short delay to ensure GUI is fully ready
|
||||
# Use a longer delay than status bar sync to avoid race conditions
|
||||
QtCore.QTimer.singleShot(3000, _deferred_auto_start)
|
||||
FreeCAD.Console.PrintMessage(
|
||||
"Robust MCP Bridge: Auto-start scheduled from InitGui (3s)\n"
|
||||
)
|
||||
# Check if auto-start is enabled before scheduling
|
||||
from preferences import get_auto_start
|
||||
|
||||
if get_auto_start():
|
||||
# Schedule auto-start after a delay to ensure GUI is fully ready.
|
||||
# InitGui.py module-level code runs early in FreeCAD startup, so we
|
||||
# need to defer the bridge start to avoid race conditions.
|
||||
# Note: We use a simple QTimer.singleShot() here because GuiWaiter
|
||||
# has timing issues when used from module-level code during startup.
|
||||
QtCore.QTimer.singleShot(3000, _auto_start_bridge)
|
||||
FreeCAD.Console.PrintMessage(
|
||||
"Robust MCP Bridge: Auto-start scheduled from InitGui (3s)\n"
|
||||
)
|
||||
else:
|
||||
FreeCAD.Console.PrintMessage(
|
||||
"Robust MCP Bridge: Auto-start disabled in preferences\n"
|
||||
)
|
||||
except Exception as e:
|
||||
FreeCAD.Console.PrintWarning(
|
||||
f"Robust MCP Bridge: Could not schedule status bar sync: {e}\n"
|
||||
|
||||
@@ -17,7 +17,7 @@ This release fixes some auto-start issues and improves the overall startup exper
|
||||
|
||||
- **Auto-start not working at FreeCAD startup**: Fixed bug where auto-start only worked when manually selecting the workbench. For FreeCAD workbench addons, `Init.py` does NOT run at startup - only `InitGui.py` module-level code runs. Auto-start logic has been moved to `InitGui.py`.
|
||||
- **Status bar not appearing after auto-start**: The status bar widget now syncs immediately after the bridge starts, instead of on a timer that ran before the bridge was ready.
|
||||
- **Integration test crashes**: Fixed race condition where the bridge could start before `FreeCAD.GuiUp` was `True`, causing Qt operations to run on a background thread and crash FreeCAD.
|
||||
- **Integration test crashes**: Fixed race condition where the bridge could start before `FreeCAD.GuiUp` was `True`, causing Qt operations to run on a background thread and crash FreeCAD. Auto-start is now deferred with `QTimer.singleShot()` to allow the GUI to stabilize.
|
||||
|
||||
### Note
|
||||
|
||||
|
||||
@@ -269,8 +269,8 @@ class FreecadMCPPlugin:
|
||||
if FREECAD_AVAILABLE:
|
||||
FreeCAD.Console.PrintMessage(
|
||||
f"MCP Bridge started (Instance ID: {self._instance_id}):\n"
|
||||
f" - JSON-RPC: {self._host}:{self._port}\n"
|
||||
)
|
||||
FreeCAD.Console.PrintMessage(f" - JSON-RPC: {self._host}:{self._port}\n")
|
||||
if self._enable_xmlrpc:
|
||||
FreeCAD.Console.PrintMessage(
|
||||
f" - XML-RPC: {self._host}:{self._xmlrpc_port}\n"
|
||||
|
||||
@@ -59,6 +59,12 @@ def _start_bridge() -> None:
|
||||
environment variables and registers the plugin with the workbench commands
|
||||
module for visibility to other components.
|
||||
|
||||
Args:
|
||||
None.
|
||||
|
||||
Returns:
|
||||
None. Early returns if bridge is already running.
|
||||
|
||||
Environment Variables:
|
||||
FREECAD_XMLRPC_PORT: XML-RPC port (default: 9875)
|
||||
FREECAD_SOCKET_PORT: JSON-RPC socket port (default: 9876)
|
||||
@@ -73,6 +79,12 @@ def _start_bridge() -> None:
|
||||
- Creates and starts a FreecadMCPPlugin instance
|
||||
- Registers the plugin with the workbench commands module
|
||||
- Prints status messages to FreeCAD.Console
|
||||
|
||||
Example:
|
||||
This function is typically called via GuiWaiter callback or directly::
|
||||
|
||||
_gui_waiter = GuiWaiter(callback=_start_bridge)
|
||||
_gui_waiter.start()
|
||||
"""
|
||||
# Check if bridge is already running (from auto-start in Init.py)
|
||||
from bridge_utils import get_running_plugin
|
||||
|
||||
@@ -278,6 +278,93 @@ class TestGuiWaiterUsage:
|
||||
assert "did not become ready" in bridge_utils_code
|
||||
|
||||
|
||||
class TestInitGuiAutoStart:
|
||||
"""Tests for auto-start logic in InitGui.py.
|
||||
|
||||
InitGui.py is the primary entry point for auto-start at FreeCAD GUI startup.
|
||||
Init.py does NOT run at startup for workbench addons, so InitGui.py must
|
||||
handle auto-start using QTimer.singleShot() to defer the bridge start.
|
||||
"""
|
||||
|
||||
@pytest.fixture
|
||||
def initgui_code(self) -> str:
|
||||
"""Load InitGui.py content."""
|
||||
return (ADDON_DIR / "InitGui.py").read_text()
|
||||
|
||||
def test_uses_single_shot_timer_for_auto_start(self, initgui_code: str) -> None:
|
||||
"""InitGui.py should use QTimer.singleShot for deferred auto-start."""
|
||||
# Should use singleShot with a delay
|
||||
assert "QTimer.singleShot" in initgui_code
|
||||
assert "_auto_start_bridge" in initgui_code
|
||||
|
||||
def test_checks_auto_start_preference(self, initgui_code: str) -> None:
|
||||
"""InitGui.py should check auto-start preference before scheduling.
|
||||
|
||||
Uses AST-based analysis to verify there's an if-condition that calls
|
||||
get_auto_start(), rather than relying on brittle string matching.
|
||||
"""
|
||||
tree = ast.parse(initgui_code)
|
||||
|
||||
def is_get_auto_start_call(node: ast.AST) -> bool:
|
||||
"""Check if node is a call to get_auto_start()."""
|
||||
if not isinstance(node, ast.Call):
|
||||
return False
|
||||
func = node.func
|
||||
# Handle direct name: get_auto_start()
|
||||
if isinstance(func, ast.Name) and func.id == "get_auto_start":
|
||||
return True
|
||||
# Handle attribute access: module.get_auto_start()
|
||||
return isinstance(func, ast.Attribute) and func.attr == "get_auto_start"
|
||||
|
||||
def contains_get_auto_start_call(node: ast.AST) -> bool:
|
||||
"""Check if node or any children contain get_auto_start call."""
|
||||
return any(is_get_auto_start_call(child) for child in ast.walk(node))
|
||||
|
||||
# Find any ast.If node whose test contains a get_auto_start call
|
||||
for node in ast.walk(tree):
|
||||
if isinstance(node, ast.If) and contains_get_auto_start_call(node.test):
|
||||
return # Found an if-condition invoking get_auto_start()
|
||||
|
||||
pytest.fail(
|
||||
"InitGui.py should have an if-condition that calls get_auto_start() "
|
||||
"to check whether auto-start is enabled before scheduling"
|
||||
)
|
||||
|
||||
def test_auto_start_bridge_function_exists(self, initgui_code: str) -> None:
|
||||
"""InitGui.py should have _auto_start_bridge callback function."""
|
||||
assert "def _auto_start_bridge" in initgui_code
|
||||
|
||||
def test_auto_start_bridge_checks_if_running(self, initgui_code: str) -> None:
|
||||
"""_auto_start_bridge should check if bridge is already running."""
|
||||
# Parse the function and check for is_bridge_running check
|
||||
tree = ast.parse(initgui_code)
|
||||
for node in ast.walk(tree):
|
||||
if isinstance(node, ast.FunctionDef) and node.name == "_auto_start_bridge":
|
||||
func_code = ast.unparse(node)
|
||||
assert "is_bridge_running" in func_code
|
||||
return
|
||||
pytest.fail("_auto_start_bridge function not found")
|
||||
|
||||
def test_auto_start_syncs_status_bar(self, initgui_code: str) -> None:
|
||||
"""_auto_start_bridge should sync status bar after starting bridge."""
|
||||
# Parse the function and check for sync_status_with_bridge call
|
||||
tree = ast.parse(initgui_code)
|
||||
for node in ast.walk(tree):
|
||||
if isinstance(node, ast.FunctionDef) and node.name == "_auto_start_bridge":
|
||||
func_code = ast.unparse(node)
|
||||
assert "sync_status_with_bridge" in func_code
|
||||
return
|
||||
pytest.fail("_auto_start_bridge function not found")
|
||||
|
||||
def test_logs_auto_start_scheduled(self, initgui_code: str) -> None:
|
||||
"""InitGui.py should log when auto-start is scheduled."""
|
||||
assert "Auto-start scheduled" in initgui_code
|
||||
|
||||
def test_logs_auto_start_disabled(self, initgui_code: str) -> None:
|
||||
"""InitGui.py should log when auto-start is disabled."""
|
||||
assert "Auto-start disabled" in initgui_code
|
||||
|
||||
|
||||
class TestAutoStartCodePaths:
|
||||
"""Tests to verify all auto-start code paths are properly handled."""
|
||||
|
||||
|
||||
Reference in New Issue
Block a user